Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 617
13 Diagnostics & fault analysis
13.7 Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x00690000 6881280 Code refresh System fault -
0x00680019
6815769 Combination MXI1/MXI2 not possible System fault -
0x0068001f
6815775 Combination of memory module/device not possible System fault -
0x00680020
6815776 Combination of module in MXI1/device not possible System fault -
0x00680021
6815777 Combination of module in MXI2/device not possible System fault -
0x007f0002
8323074 Communication error between device and device module No response C01501
0x0091000e 9502734 Communication task: Standstill > 3 s Fault C01230
0x007f0003 8323075 Communication with module in MXI1 interrupted Information -
0x007f0004
8323076 Communication with module in MXI2 interrupted Information -
0x00920001
9568257 Communication with safety module interrupted Information -
0x008c001a
9175066 ConnectTable active Information -
0x0068000e
6815758 Control card incompatible System fault -
0x00680000
6815744 Control card is defective System fault -
0x00680008
6815752 Control card is defective System fault -
0x00780008
7864328 Control card is defective (UB18 neg.) System fault -
0x00780004
7864324 Control card is defective (UB24) System fault -
0x00780006
7864326 Control card is defective (UB8) System fault -
0x00780007
7864327 Control card is defective (VCC15 neg.) System fault -
0x00780005
7864325 Control card is defective (VCC15) System fault -
0x00780009
7864329 Control card is defective (VCC5) System fault -
0x006f0000
7274496 Control card: Supply voltage (24 V DC) too low Trouble -
0x00750001
7667713 Controller enabled Information -
0x00750003
7667715 Controller in STO state Information -
0x007b0047
8060999 Controller: Clamp operation Information -
0x007b0035
8060981 Controller: Overload during acceleration phases Fault -
0x00750005
7667717 Controller: Pulse inhibit is active Information -
0x00770009
7798793 CPU: Overtemperature Warning -
0x00770008
7798792 CPU: Temperature > C00126 No response C00589
0x0077000e 7798798 CPU: thermal detector is defective Fault C00588
0x0091000f 9502735 Cyclic task: Standstill > 60 s Information -
0x0077000d
7798797 DC-bus capacitor: thermal detector is defective Fault C00588
0x007b000e 8060942 DC-bus overvoltage Trouble C00600
0x007b000f 8060943 DC-bus undervoltage Trouble -
0x00b8000d
12058637 Deceleration has been limited Information C02716/3
0x00780001 7864321 Device utilisation Ixt > 100 % Fault -
0x00780000
7864320 Device utilisation Ixt > C00123 Warning C00604
0x00990003 10027011 DFIN (MXI1): Signal error enable/lamp control Warning C13041
0x00990004 10027012 DFIN (MXI1): Supply cannot be corrected anymore Warning C13042
0x00990000 10027008 DFIN (MXI1): Track error A-/A Fault C13040
0x00990001 10027009 DFIN (MXI1): Track error B-/B Fault C13040
0x00990002 10027010 DFIN (MXI1): Track error Z-/Z Fault C13040
0x00aa0003 11141123 DFIN (MXI2): Signal error enable/lamp control Warning C14041
0x00aa0004 11141124 DFIN (MXI2): Supply cannot be corrected anymore Warning C14042
0x00aa0000 11141120 DFIN (MXI2): Track error A-/A Fault C14040
0x00aa0001 11141121 DFIN (MXI2): Track error B-/B Fault C14040
0x00aa0002 11141122 DFIN (MXI2): Track error Z-/Z Fault C14040
0x00990005 10027013 DFOUT (MXI1): Maximum frequency reached Warning C13080
0x00aa0005 11141125 DFOUT (MXI2): Maximum frequency reached Warning C14080
0x0090000c 9437196 Disconnection in the case of par. storage Fault -
0x006a0011
6946833 Division by zero Fault -
0x007b0011
8060945 Earth fault detected Fault -
0x0068001d
6815773 Electronic nameplate: Checksum error Warning -
hex dec Error message Response (Lenze setting) can be set in
Comentarios a estos manuales