Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 871
14 Parameter reference
14.2 Parameter list | C02626
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02626
C02627
C02637
Parameter | Name:
C02626 | Manual jog:Index Stop position
Data type: INTEGER_32
Index: 21949
d
= 55BD
h
From software version V5.0
Selection of the breakpoint positions for "Manual jog with breakpoint
" mode.
• In connection with a function block instance of type L_PosPositionerTable:
The index [1...75] of the table position in the VTPOS table has to be specified, which contains the intermediate
stop position x that is to be used.
• In connection with a function block instance of type L_PosProfileTable:
The index [1...4] of the profile data set in the VTPOS table has to be specified, which contains the intermediate
stop position x that is to be used.
Basic function "Manual jog
"
Setting range (min. value | unit | max. value)
075
Subcodes Lenze setting Info
C02626/1 0 Index of the breakpoint positions 1 ... 16
C02626/...
C02626/16
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C02627 | Manual jog:Selected Stop position
Data type: INTEGER_32
Index: 21948
d
= 55BC
h
From software version V5.0
Display of the breakpoint positions selected via C02626/1...16
for "Manual jog with breakpoints".
Basic function "Manual jog
"
Display range (min. value | unit | max. value)
-214748.3648 Unit 214748.3647
Subcodes Info
C02627/1 Breakpoint position 1 ... 16
C02627/...
C02627/16
Read access Write access CINH PLC STOP No transfer Scaling factor: 10000
Parameter | Name:
C02637 | MAN_dnSpeedOverride_n
Data type: INTEGER_32
Index: 21938
d
= 55B2
h
From software version V5.0
Display of the speed override for the basic function "Manual jog
".
Display range (min. value | unit | max. value)
-200.00 % 200.00
Read access Write access CINH PLC STOP No transfer Scaling factor: 100