Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 101
4 Drive interface
4.3 Device states
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.3.4 "Device is switched on" state
The drive is in this device status if the DC bus voltage is applied and the controller is still inhibited
by the user (controller inhibit).
The bus systems are running and the terminals and encoders are evaluated.
The monitoring functions are active.
The controller can be parameterised and device commands can be executed to a limited extent.
The functions of the user task can be used.
Precondition: The application has started (status display in C02108
).
The basic drive functions cannot be used yet.
If the controller is enabled, the motor builds up a torque.
4.3.5 "Operation" state
In this device state the motor follows its setpoint according to the basic drive function selected.
Danger!
If automatic restart is enabled (C00142 = "1: Enabled"), the drive can restart
automatically from the "Trouble" and "Safe torque off" device states when the trouble or
request for "Safe torque off active" has been eliminated!
Automatic restart after mains connection/trouble...
( 104)
LED DRIVE READY LED DRIVE ERROR Display in C00183
OFF 90: Drive is switched on
LED DRIVE READY LED DRIVE ERROR Display in C00183
OFF 0: Operation