11 Basic drive functions
11.6 Homing
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Mode 8: positive direction to touch probe
Procedure:
1. Movement in positive direction with profile data set 1.
2. The following positive edge of the touch probe sensor sets the reference.
3. Absolute positioning to target position (C02643
) with profile data set 2 (if C02641 ="0").
Mode 9: negative direction to touch probe
Procedure:
1. Movement in negative direction with profile data set 1.
2. The following positive edge of the touch probe sensor sets the reference.
3. Absolute positioning to target position (C02643
) with profile data set 2 (if C02641 ="0").
Touch probe/zero pulse
Touch probe/zero pulse