11 Basic drive functions
11.12 Brake control
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.12.3 Mode 0: Brake control is switched off
If the mode 0 is selected in C02580, the brake control is switched off.
If a motor brake control module is available, it will not be triggered.
The brake monitoring function is not active.
A potential fault reported by the brake control is reset automatically.
The output signals of the system block LS_Brake are reset:
BRK_dnState = 0
BRK_bReleaseBrakeOut = FALSE
BRK_bBrakeReleased = FALSE
BRK_bError = FALSE