Lenze 9400 Manual de usuario Pagina 859

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 954
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 858
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 859
14 Parameter reference
14.2 Parameter list | C02568
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02568
C02569
Parameter | Name:
C02568 | Motor interface: % signals
Data type: INTEGER_32
Index: 22007
d
= 55F7
h
Display of the scaled signals of the motor interface.
Display range (min. value | unit | max. value)
-200.00 % 200.00
Subcodes Info
C02568/1 MI_dnPosCtrlAdaptLoad_n
C02568/2 MI_dnPosCtrlAdaptMotor_n
C02568/3 MI_dnSpeedCtrlAdapt_n
C02568/4 MI_dnTorqueHighLimit_n
C02568/5 MI_dnTorqueLowLimit_n
C02568/6 MI_dnTorqueCtrlAdapt_n
C02568/7 MI_dnFluxSetpoint_n
C02568/8 MI_dnInertiaAdapt_n
C02568/9 MI_dnBoostSet_n
C02568/10 MI_dnTorqueAdd_n
Read access Write access CINH PLC STOP No transfer Scaling factor: 100
Parameter | Name:
C02569 | Motor interface.: Dig. signals
Data type: UNSIGNED_32
Index: 22006
d
= 55F6
h
Display of the digital signals of the motor interface.
Selection list (read only)
0 FALSE
1 TRUE
Subcodes Info
C02569/1 Reserved
C02569/2 MI_bResetSpeedCtrlIntegrator
C02569/3 MI_bLimitationActive
C02569/4 MI_bPosCtrlLimited
C02569/5 MI_bSpeedSetPointLimited
C02569/6 MI_bSpeedCtrlLimited
C02569/7 MI_bTorqueSetpointLimited
C02569/8 MI_bCurrentSetpointLimited
C02569/9 MI_bSpeedBelowC19
C02569/10 MI_bSpeedFollowingError
C02569/11 MI_bMotorOverloadWarning
C02569/12 MI_bMotorOrientationInverse
C02569/13 MI_bFlyingSyncBusy
C02569/14 MI_bClampIsActive
C02569/15 MI_bMagnetisationFinished
C02569/16 MI_bFlyingSyncBlocked
Read access Write access CINH PLC STOP No transfer Scaling factor: 1