5 Motor interface
5.8 Parameterisable additional functions
206
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.8.2 Field weakening for synchronous machines
This function is available from software version V2.0!
If required, the field weakening mode can be switched on in C00093
for synchronous machines.
[5-28] Voltage/speed characteristic with switched-on field weakening
[5-29] Calculation of the maximally reachable speed with switched-on field weakening
[5-30] Speed/torque characteristics of a synchronous servo motor with field weakening
Note!
Function only possible for servo control!
Armature control range
Field weakening range
When field weakening is switched on, the motor
magnetising current is increased from 0 A to the maximally
effective magnetising current via an internal control loop
when the voltage limit is reached.
As a result, a higher speed can be reached at the same
motor voltage or DC-bus voltage.
n
U
motor
n
max
n
rated_mot
800V
2U
rated_mot
--------------------------------------
=
Standstill torque
Rated torque
Characteristic for continuous operation
Limit characteristic at mains voltage of 400 V without field weakening
Limit characteristic with field weakening
0
10
20
30
40
50
60
M [Nm]
0 1500 3000 4500
0
1
n [rpm]
Vista de pagina 205