13 Diagnostics & fault analysis
13.7 Error messages of the operating system
618
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x0068001b 6815771 Electronic nameplate: Communication error Warning -
0x0078000a
7864330 Electronic nameplate: Data are incompatible Information -
0x007b0030
8060976 Electronic nameplate: Data loaded Information -
0x007b0039
8060985 Electronic nameplate: Data outside parameter limits Information -
0x007b0032
8060978 Electronic nameplate: Encoder protocol unknown Information -
0x007b0033
8060979 Electronic nameplate: Encoder signal unknown Information -
0x007b0031
8060977 Electronic nameplate: Not found Information -
0x007b003e
8060990 Encoder monitoring: Pulse deviation detected No response C00621
0x007b001b 8060955 Encoder: Open circuit Fault C00580
0x007b002c 8060972 EnDat encoder: Battery empty Information -
0x007b004f
8061007 EnDat encoder: Command error Information -
0x007b0050
8061008 EnDat encoder: Initial position error Information -
0x007b0026
8060966 EnDat encoder: Lamp error Information -
0x007b002b
8060971 EnDat encoder: Overcurrent Information -
0x007b0029
8060969 EnDat encoder: Overvoltage Information -
0x007b0028
8060968 EnDat encoder: Position error Information -
0x007b0027
8060967 EnDat encoder: Signal error Information -
0x007b004e
8061006 EnDat encoder: Transmission error Information -
0x007b002a
8060970 EnDat encoder: Undervoltage Information -
0x00910011
9502737 Error during initialisation System fault -
0x006a0002
6946818 Error during the update of inputs and outputs Fault -
0x006a0017
6946839 Error in control configuration System fault -
0x00750000
7667712 External error Fault C00581
0x007b002d 8060973 Failure of motor phase U No response C00597
0x007b002e 8060974 Failure of motor phase V No response C00597
0x007b002f 8060975 Failure of motor phase W No response C00597
0x006a0010 6946832 Faulty application parameter Fault -
0x006a0001
6946817 Faulty program download Fault -
0x008c0002
9175042 File DeviceCFG.dat is defective Fault -
0x008c0008
9175048 File DeviceCFG.dat is invalid Fault -
0x008c0005
9175045 File DeviceCFG.dat is missing Fault -
0x008c0001
9175041 File ProjectList.dat is defective Fault -
0x008c0007
9175047 File ProjectList.dat is invalid Fault -
0x008c0004
9175044 File ProjectList.dat is missing Fault -
0x008c0000
9175040 File ProjectSelection.dat is defective Fault -
0x008c0006
9175046 File ProjectSelection.dat is invalid Fault -
0x008c0003
9175043 File ProjectSelection.dat is missing Fault -
0x0068001a
6815770 Firmware has been changed Information -
0x0068001e
6815774 Firmware incompatible to control card System fault -
0x006a0000
6946816 General error in the application Fault -
0x00910003
9502723 Heartbeat not periodic System fault -
0x00770010
7798800 Heatsink: fan is defective Fault C00610
0x00770001 7798785 Heatsink: Overtemperature Fault -
0x00770000
7798784 Heatsink: Temperature > C00122 Warning C00582
0x0077000a 7798794 Heatsink: thermal detector is defective Fault C00588
0x007b003b 8060987 Hiperface encoder: Command error Information -
0x007b003d
8060989 Hiperface encoder: Initial position error Information -
0x007b003a
8060986 Hiperface encoder: Transmission error Information -
0x007b003c
8060988 Hiperface encoder: Unknown encoder Information -
0x00b80019
12058649 Homing mode not allowed Fault -
0x006a0006
6946822 IdleTask: Overflow Fault -
0x00790000
7929856 Incorrect device command transfer System fault -
hex dec Error message Response (Lenze setting) can be set in
Comentarios a estos manuales