14 Parameter reference
14.2 Parameter list | C02772
892
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02772
C02773
C02774
Parameter | Name:
C02772 | Starting angle
Data type: INTEGER_32
Index: 21803
d
= 552B
h
From software version V7.0
Basic function "Manual jog open loop
"
Setting range (min. value | unit | max. value)
-180.0 ° 180.0
Subcodes Lenze setting Info
C02772/1 0.0 ° Startangle 1
C02772/2 0.0 ° Startangle 2
C02772/3 0.0 ° Startangle 3
C02772/4 0.0 ° Startangle 4
Read access Write access CINH PLC STOP No transfer Scaling factor: 10
Parameter | Name:
C02773 | Current
Data type: INTEGER_32
Index: 21802
d
= 552A
h
From software version V7.0
100 % ½ I
max_device
(C00022)
Basic function "Manual jog open loop
"
Setting range (min. value | unit | max. value)
0.00 % 100.00
Subcodes Lenze setting Info
C02773/1 10.00 % Current 1
C02773/2 10.00 % Current 2
C02773/3 10.00 % Current 3
C02773/4 10.00 % Current 4
Read access Write access CINH PLC STOP No transfer Scaling factor: 100
Parameter | Name:
C02774 | Acceleration time
Data type: INTEGER_32
Index: 21801
d
= 5529
h
From software version V7.0
Basic function "Manual jog open loop
"
Setting range (min. value | unit | max. value)
0.001 s 2147483.647
Subcodes Lenze setting Info
C02774/1 1.000 s Acceleration time 1
C02774/2 1.000 s Acceleration time 2
C02774/3 1.000 s Acceleration time 3
C02774/4 1.000 s Acceleration time 4
Read access Write access CINH PLC STOP No transfer Scaling factor: 1000