13 Diagnostics & fault analysis
13.7 Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Jerk has been limited [0x00b8000e]
Position target outside the software limit positions [0x00b8000f]
Maximum speed exceeded [0x00b80010]
Maximum acceleration exceeded [0x00b80011]
Module ID (decimal) Error ID (decimal)
184: Basic drive functions 14
Response (Lenze setting printed in bold) Setting: C02716/3 ( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
The requested S-ramp time is lower than the minimum
S-ramp time set in C02706
and has been limited to this S-
ramp time.
• Increase S-ramp time of the traversing profile of the
basic function (manual jog, homing, or positioning).
• Reduce minimum S-ramp time (C02706
).
Deactivate monitoring of the limit values by the basic
function "Limiter".
Module ID (decimal) Error ID (decimal)
184: Basic drive functions 15
Response (Lenze setting printed in bold) Setting: C02716/2 ( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
It was tried to position to a target outside the software
limit positions.
• Select a target within the software limit positions.
Increase permissible traversing range (change setting
of the software limit positions).
Deactivate monitoring of the software limit positions
by the basic function "Limiter".
Module ID (decimal) Error ID (decimal)
184: Basic drive functions 16
Response (Lenze setting printed in bold) Setting: C02716/3 ( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
The max. speed parameterised in C02703 or C00011 has
been exceeded.
• Reduce speed.
• Increase maximum speed (C02703
).
Deactivate monitoring of the limit values by the basic
function "Limiter".
Module ID (decimal) Error ID (decimal)
184: Basic drive functions 17
Response (Lenze setting printed in bold) Setting: C02716/3 ( Adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
The max. acceleration parameterised in C02705 has
been exceeded.
• Reduce acceleration.
• Increase maximum acceleration (C02705
).
Deactivate monitoring of the limit values by the basic
function "Limiter".