Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 621
13 Diagnostics & fault analysis
13.7 Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x00680015 6815765 MXI1: Module has been changed Information or warning locked if
the hardware type has also
changed.
-
0x0068000a
6815754 MXI1: Module is defective or missing Fault -
0x008c000d
9175053 MXI1: Module is missing or incompatible Fault -
0x008c000f
9175055 MXI1: PROFIBUS module is missing or incompatible Fault C00615/2
0x00680010 6815760 MXI1: Wrong module System fault -
0x008c0018
9175064 MXI2: CAN module is missing or incompatible Fault C00615/3
0x008c0014 9175060 MXI2: Digital frequency module is missing or incompatible Fault C00615/3
0x008c0012 9175058 MXI2: Ethernet module is missing or incompatible Fault C00615/3
0x008c0016 9175062 MXI2: ICM module is missing or incompatible Fault C00615/3
0x00680005 6815749 MXI2: Module changed during operation Warning locked -
0x00680016
6815766 MXI2: Module has been changed Information or warning locked if
the hardware type has also
changed.
-
0x0068000b
6815755 MXI2: Module is defective or missing System fault -
0x008c000e
9175054 MXI2: Module is missing or incompatible Fault -
0x008c0010
9175056 MXI2: PROFIBUS module is missing or incompatible Fault C00615/3
0x00680011 6815761 MXI2: Wrong module System fault -
0x00b8000a
12058634 Negative direction of rotation limited Information C02716/1
0x00b80002 12058626 Negative limit switch has triggered Quick stop by trouble -
0x00b80008
12058632 Negative software limit switch overtravelled Quick stop by trouble C02716/2
0x006a0003 6946819 New applications loaded Information -
0x00910002
9502722 No heartbeat signal detected System fault -
0x0090000a
9437194 No parameters for module in MXI1 Fault C00615/2
0x0090000b 9437195 No parameters for module in MXI2 Fault C00615/3
0x007b0010 8060944 Overcurrent detected Fault -
0x00900000
9437184 Parameter set faulty Fault -
0x00900003
9437187 Parameter set loaded Information -
0x00900005
9437189 Parameter set restored Fault -
0x00900002
9437186 Parameter set saved Information -
0x00900009
9437193 Parameter set: type of standard device has been changed Information -
0x00900007
9437191 Parameter set: Version conflict Fault -
0x006a0015
6946837 PDO mapping (MXI1): Faulty configuration Fault -
0x006a0016
6946838 PDO mapping (MXI2): Faulty configuration Fault -
0x00b80000
12058624 PLC configuration invalid Fault -
0x007d0001
8192001 PLC configuration invalid Fault -
0x007b0037
8060983 PLC configuration invalid Fault -
0x00750006
7667718 PLC configuration invalid Fault -
0x006a0012
6946834 Pointer access in impermissible memory area Fault -
0x007b004a
8061002 Pole position identification cancelled Fault C00640
0x00b8000f 12058639 Position target outside the software limit positions Quick stop by trouble C02716/2
0x00910010 9502736 Position value faulty Fault -
0x00b80009
12058633 Positive direction of rotation limited Information C02716/1
0x00b80001 12058625 Positive limit switch has triggered Quick stop by trouble -
0x00b80007
12058631 Positive software limit switch overtravelled Quick stop by trouble C02716/2
0x00680014 6815764 Power section has been changed Information or warning locked if
the hardware type has also
changed.
-
0x0068000f
6815759 Power section incompatible System fault -
0x00680001
6815745 Power section is defective System fault -
0x00680009
6815753 Power section is defective System fault -
0x007b0042
8060994 Power section is defective System fault -
0x008c000a
9175050 Project not available Fault -
hex dec Error message Response (Lenze setting) can be set in