Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 807
14 Parameter reference
14.2 Parameter list | C00625
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00625
C00635
C00636
C00637
Parameter | Name:
C00625 | CAN behaviour in case of fault
Data type: UNSIGNED_8
Index: 23950
d
= 5D8E
h
Mapping of the CANopen object I-1029 (see DS301 V4.02).
"CAN on board" system bus
Selection list (Lenze setting printed in bold)
0 Pre-operational state
1 No state change
2 Stopped state
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00635 | Resp to new firmw. standard dev.
Data type: UNSIGNED_32
Index: 23940
d
= 5D84
h
Selection list (Lenze setting printed in bold)
1Fault
6 Information
5 Warning
4 Warning locked
3 Quick stop by trouble
0 No response
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00636 | Resp. to new module in MXI1
Data type: UNSIGNED_32
Index: 23939
d
= 5D83
h
Selection list (Lenze setting printed in bold)
1Fault
6 Information
5 Warning
4 Warning locked
3 Quick stop by trouble
0 No response
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00637 | Resp. to new module in MXI2
Data type: UNSIGNED_32
Index: 23938
d
= 5D82
h
Selection list (Lenze setting printed in bold)
1Fault
6 Information
5 Warning
4 Warning locked
3 Quick stop by trouble
0 No response
Read access Write access CINH PLC STOP No transfer Scaling factor: 1