Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 53
4 Drive interface
4.2 Device commands
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.2.9 Start application
The C00002 = "31: Start application" device command is used to start the active application in the
controller.
[4-17] "Start application" function
The number of the currently active application is displayed in C00007.
The current program status is displayed in C02108
.
The active function state of the application is displayed in C02530
.
Tip!
This device command can also be activated via the icon in the Toolbar.
Possible status displays for this device command
Related device commands
Stop application
( 54)
Activate application
( 47)
Save selected application
( 48)
Memory module MM
9400
RAM
Firmware Application 1Application
Application 2
Application 3
Status (C00003) Meaning
2065666 Device command in process
2031616 Device command executed successfully
2031617 General fault