Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 803
14 Parameter reference
14.2 Parameter list | C00607
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00607
C00610
C00611
Parameter | Name:
C00607 | Resp. to max. speed reached
Data type: UNSIGNED_32
Index: 23968
d
= 5DA0
h
Response if adjustable speed threshold (C00596) is reached.
Selection list (Lenze setting printed in bold)
1Fault
2Trouble
5 Warning
4 Warning locked
3 Quick stop by trouble
0 No response
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00610 | Resp. to failure heatsink fan
Data type: UNSIGNED_32
Index: 23965
d
= 5D9D
h
Response if fan speed of heatsink fan is too low.
Selection list (Lenze setting printed in bold)
1Fault
5 Warning
0 No response
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00611 | Resp. to failure integral fan
Data type: UNSIGNED_32
Index: 23964
d
= 5D9C
h
Response if fan speed of internal fan is too low.
Selection list (Lenze setting printed in bold)
1Fault
5 Warning
0 No response
Read access Write access CINH PLC STOP No transfer Scaling factor: 1