L Firmware 1.37 - 09/2006 641
9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C02712
C02712
C02713
C02714
C02715
Parameter | Name:
C02712 | Decel. time lim. speed
Data type: UNSIGNED_32
Index: 21863
d
= 5567
h
Basic function "Limiter"
Display range
(min. value | unit | max. value)
0 ms 10000
Subcodes Information
C02712/1 Deceleration times for limited speed 1 ... 4
C02712/2
C02712/3
C02712/4
; Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02713 | Max. dist. manual control
Data type: UNSIGNED_32
Index: 21862
d
= 5566
h
Basic function "Limiter"
Setting range
(min. value | unit | max. value) Lenze setting
0.0000 Unit 214748.3647 360.0000 Unit
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10000
Parameter | Name:
C02714 | Max. dist. manual control
Data type: UNSIGNED_32
Index: 21861
d
= 5565
h
Basic function "Limiter"
Display range
(min. value | unit | max. value)
0 Incr. 2147483647
; Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02715 | Limitation active
Data type: UNSIGNED_32
Index: 21860
d
= 5564
h
Basic function "Limiter"
Selection list
(display only)
0 Deactivated
1Activated
; Read access Write access CINH PLC STOP No transfer COM MOT