Error messages of the operating system
522 Firmware 1.37 - 09/2006 L
CAN module (MXI2): Heartbeat error index 22 [0x00ad0015]
CAN module (MXI2): Heartbeat error index 23 [0x00ad0016]
CAN module (MXI2): Heartbeat error index 24 [0x00ad0017]
CAN module (MXI2): Heartbeat error index 25 [0x00ad0018]
CAN module (MXI2): Heartbeat error index 26 [0x00ad0019]
CAN module (MXI2): Heartbeat error index 27 [0x00ad001a]
Response (Lenze setting printed in bold) Setting: C14613/22 (; Adjustable response)
: None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
CANopen communication module in MXI2: No heartbeat
telegram received from node 22.
See remedy for "Heartbeat error index 1".
Response (Lenze setting printed in bold) Setting: C14613/23 (; Adjustable response)
: None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
CANopen communication module in MXI2: No heartbeat
telegram received from node 23.
See remedy for "Heartbeat error index 1".
Response (Lenze setting printed in bold) Setting: C14613/24 (; Adjustable response)
: None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
CANopen communication module in MXI2: No heartbeat
telegram received from node 24.
See remedy for "Heartbeat error index 1".
Response (Lenze setting printed in bold) Setting: C14613/25 (; Adjustable response)
: None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
CANopen communication module in MXI2: No heartbeat
telegram received from node 25.
See remedy for "Heartbeat error index 1".
Response (Lenze setting printed in bold) Setting: C14613/26 (; Adjustable response)
: None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
CANopen communication module in MXI2: No heartbeat
telegram received from node 26.
See remedy for "Heartbeat error index 1".
Response (Lenze setting printed in bold) Setting: C14613/27 (; Adjustable response)
: None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
CANopen communication module in MXI2: No heartbeat
telegram received from node 27.
See remedy for "Heartbeat error index 1".