9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C02533
618 Firmware 1.37 - 09/2006 L
C02533
C02534
C02535
C02536
C02537
C02538
C02539
C02540
Parameter | Name:
C02533 | Time unit
Data type: UNSIGNED_32
Index: 22042
d
= 561A
h
Drive interface
Selection list (display only)
2s
; Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02534 | User-defined time unit
Data type: VISIBLE_STRING
Index: 22041
d
= 5619
h
Drive interface
; Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02535 | User-defined unit
Data type: VISIBLE_STRING
Index: 22040
d
= 5618
h
Drive interface
; Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02536 | Cycle
Data type: UNSIGNED_32
Index: 22039
d
= 5617
h
Drive interface
Setting range (min. value | unit | max. value) Lenze setting
0.0000 Unit 214748.3647 360.0000 Unit
; Read access ; Write access ; CINH PLC STOP No transfer COM MOT Scaling factor: 10000
Parameter | Name:
C02537 | Speed unit
Data type: VISIBLE_STRING
Index: 22038
d
= 5616
h
Drive interface
; Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02538 | Acceleration unit
Data type: VISIBLE_STRING
Index: 22037
d
= 5615
h
Drive interface
; Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02539 | Maximum position to be displayed
Data type: INTEGER_32
Index: 22036
d
= 5614
h
Drive interface
Display range (min. value | unit | max. value)
-214748.3647 Unit 214748.3647
; Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10000
Parameter | Name:
C02540 | Max. speed to be displayed
Data type: INTEGER_32
Index: 22035
d
= 5613
h
Drive interface
Display range (min. value | unit | max. value)
-214748.3647 Unit/s 214748.3647
; Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10000
Comentarios a estos manuales