9400 HighLine | Parameter setting & configuration
Standard TAs
Introduction
242 Firmware 1.37 - 09/2006 L
11.1 Introduction
11.1.1 Application examples
Dosing drives
r Both dosing drives are operated in speed-controlled mode and determine the mix ratio
with their speed:
[11-1] Example: Dosing drives with adjustable mix ratio v
1
/v
2
r Technical connections/machine parameters:
n Mains
o System bus (CAN)
p Drive 1 with TA "actuator – speed"
q Drive 2 with TA "actuator – speed"
i = gearbox factor
n = Load reference speed in [rpm]
v = Reference speed in [m/s]
d = roll diameter in [m]
d
1
n
1
v
1
i
1
d
2
n
2
i
2
v
2
Parameters Information
C00011
Motor reference speed
C02520
Gearbox fact. numer. motor
C02521
Gearbox fact. denom. motor
C02542 Load reference speed
Highlighted in grey = display parameter
Parameters Information
C02524
Feed constant roll diameter in [m] * π
C02525
Selection of the unit [m]
Highlighted in grey = display parameter
Load reference speed [min-1]
Motor reference speed [min-1]
Gearbox factor
-------------------------------------------------------------------------------=
Reference speed [m/s]
Roll diameter [m] π Load reference speed [min-1]⋅⋅
60
-------------------------------------------------------------------------------------------------------------------------------------=
Comentarios a estos manuales