L Firmware 1.37 - 09/2006 465
9400 HighLine | Parameter setting & configuration
Diagnostics & error analysis
Error messages of the operating system
CPU: Overtemperature [0x00770009]
Heatsink: Temperature sensor defective [0x0077000a]
Inside the device: Temperature sensor defective [0x0077000b]
Motor: Temperature sensor defective [0x0077000c]
DC-bus capacitor: Temperature sensor defective [0x0077000d]
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
CPU temperature higher than fixed limit temperature
(85 °C).
Controller ambient temperature too high.
Dirty fan or ventilation slots.
Check control cabinet temperature.
Clean filter.
Clean controller.
Response (Lenze setting printed in bold) Setting: C00588 (; Adjustable response)
; None System fault : Fault Trouble Quick stop by trouble Warning locked ; Warning Information
Cause Remedy
Encoder for heatsink temperature supplies undefined
values.
Check control cabinet temperature, maybe it is too low.
Response (Lenze setting printed in bold) Setting: C00588 (; Adjustable response)
; None System fault : Fault Trouble Quick stop by trouble Warning locked ; Warning Information
Cause Remedy
Encoder for interior temperature supplies undefined
values.
Check control cabinet temperature, maybe it is too low.
Response (Lenze setting printed in bold) Setting: C00594 (; Adjustable response)
; None System fault : Fault Trouble Quick stop by trouble Warning locked ; Warning Information
Cause Remedy
The signals of the connected encoder of the motor
temperature detection (resolver at X7 or encoder at X8)
are outside the defined operating range of detection.
Check bonding of the encoder cable at the motor and
controller.
Check selection of the motor temperature sensor in
C01190
and make sure that it complies with the
assembly in the motor.
Possibly switch off temperature sensor monitoring
(C00594
="0").
If a PTC is in the motor, activate the monitoring of the
PTC temperature in C00585
instead.
Response (Lenze setting printed in bold) Setting: C00588 (; Adjustable response)
; None System fault : Fault Trouble Quick stop by trouble Warning locked ; Warning Information
Cause Remedy
Encoder for capacitor temperature supplies undefined
values.
Check control cabinet temperature, maybe it is too low.
Vista de pagina 464