L Firmware 1.37 - 09/2006 475
9400 HighLine | Parameter setting & configuration
Diagnostics & error analysis
Error messages of the operating system
Failure of motor phase U [0x007b002d]
Failure of motor phase V [0x007b002e]
Failure of motor phase W [0x007b002f]
Electronic nameplate: Data loaded [0x007b0030]
Electronic nameplate: Not found [0x007b0031]
Electronic nameplate: Unknown encoder protocol [0x007b0032]
Response (Lenze setting printed in bold) Setting: C00597 (; Adjustable response)
: None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning Information
Cause Remedy
U phase interruption of motor cable. Check cabling between controller and motor.
Check parameter setting (C00599
).
Response (Lenze setting printed in bold) Setting: C00597 (; Adjustable response)
: None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning Information
Cause Remedy
V phase interruption of the motor cable. Check cabling between controller and motor.
Check parameter setting (C00599
).
Response (Lenze setting printed in bold) Setting: C00597 (; Adjustable response)
: None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning Information
Cause Remedy
W phase interruption of the motor cable. Check cabling between controller and motor.
Check parameter setting (C00599
).
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause Remedy
New electronic nameplate (ENP) has been found. - (Information only)
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause Remedy
Electronic nameplate (ENP) is not available. - (Information only)
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause Remedy
The connected motor with feedback is not supported by
the controller firmware.
Check drive dimensioning.