L Firmware 1.37 - 09/2006 249
9400 HighLine | Parameter setting & configuration
Standard TAs
TA "Actuator – speed" | Machine parameters
11.2.3 Machine parameters
O Tip!
In the »Engineer« the most important machine parameters can be adapted to the
machine on the Application parameter tab directly in the topmost Overview dialog
level:
Detailed information for selecting and entering the machine parameters can be
found in the chapter "Drive interface
".Machine parameters (C 35)
Short overview of machine parameters
The machine parameters describe e.g. the motor end of the mechanics
used.
The setting of the machine parameters in the »Engineer» is carried out on
the Application parameters tab in the dialog level Overview Drive
interface .
Parameters Lenze setting
Value Unit
C00173 Mains - voltage 400/415 V
C00174
Threshold undervoltage (LU) 285 V
C00600
Resp. to DC bus overvoltage Trouble
C02520
Gearbox fact. numer. motor 1
C02521
Gearbox fact. denom. motor 1
C02527
Motor mounting direction Motor rotating CW
C02570
Controller configuration Phase control
C02522
Gearbox fact. numer. load 1
C02523
Gearbox fact. denom. load 1
Description of the mechanics (load, tool)
C02528
Traversing range Unlimited
C02524
Feed constant 360.0000 Unit
C02525
Unit °
C02526
User-defined unit °
C02533 Time unit s
C00273/1 Motor moment of inertia Motor-dependent kg cm
2
C00273/2 Load moment of inertia 0.00 kg cm
2
M