Vista de pagina 314
L Firmware 1.37 - 09/2006 315
9400 HighLine | Parameter setting & configuration
TAs for interconnection via electrical shaft
TA "Electronic gearbox" | "Manual jog" mode
12.2.7 "Manual jog" mode
In the "Manual jog" mode (C03006 = "4") the drive is decoupled from the electrical shaft
and the basic function "Manual jog" is enabled:
[12-18] "Manual jog" mode (schematic diagram)
r Parameter setting: Tab Application parameter Dialog level Overview Manual jog
O Tip!
Detailed information on the manual jog function can be found in chapter "Basic
drive functions" subchapter "Manual jog
". (C 156)
v
t
LS_ManualJog
n
t
è
ç
n
t
LS_Positioner
0-100 100 200
LS_Homing
C03006 = 4
t
M
Slave
Parameters Lenze setting
Value Unit
C02620 Manual jog speed 1 360.0000 Unit/s
C02621
Manual jog speed 2 720.0000 Unit/s
C02622
Manual acceleration 360.0000 Unit/s
2
C02623 Manual deceleration 1440.0000 Unit/s
2
C02624 Inaccuracy time of manual traversing 0.100 s
C03007 Positive manual jog Inactive
C03008 Negative manual jog Inactive
Control inputs of the function Signal configuration
Lenze setting Control input (Multiplexer parameters)
C03007 Activate positive manual jog C03155/2
C03008 Activate negative manual jog C03155/3
FALSE Activate 2. speed C03155/4
FALSE Retract limit switch C03155/5