Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37 Manual de usuario Pagina 235

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 679
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 234
L Firmware 1.37 - 09/2006 235
9400 HighLine | Parameter setting & configuration
Technology applications (TAs)
Commissioning using the »Engineer«
10.2 Commissioning using the »Engineer«
Basic procedure
1. Start »Engineer«.
2. Open available project or create a new project.
3. Assign each controller to a technology application from the catalogue.
4. For a project with several interconnected devices:
Insert network and machine application .
Make suitable network settings.
Specialise the predefined ports to concrete interfaces for the devices involved in the
network on the Ports tab.
Interconnect the ports conveniently inside the machine application.
5. Parameterise the application(s).
6. Update devices.
7. Go online.
8. Download application(s) into the controller(s).
9. Confirm Dialog box Start application with Yes, all devices.
10. Confirm Dialog box Enable controller with Yes, all devices.
11. Control application(s) via terminals or network.
Note!
The downloaded application is basically stored in the first application memory
location of the controller.
Vista de pagina 234
1 2 ... 230 231 232 233 234 235 236 237 238 239 240 ... 678 679

Comentarios a estos manuales

Sin comentarios