Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37 Manual de usuario Pagina 23

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 679
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 22
L Firmware 1.37 - 09/2006 23
9400 HighLine | Parameter setting & configuration
Introduction
Communicating with the controller
4. Click Find controller path to find the controller in the selected bus system.
•The Address assignment dialog box appears:
5. Select the corresponding controller from the Identified field devices list field.
6. Click OK.
•The Address assignment dialog box is closed and the selected Controller access
path (e.g. "DDCMP:/") is indicated in the Assignment of offline controllers dialog
box.
7. Click Connect.
The dialog box is closed and the online connection with the controller is built up.
In the Project view, a yellow icon indicates the online connection with the
controller:
Now you can use the icons and to easily build up and end a connection with the
controller. The communication settings are only required when communication with a
controller is built up for the first time.
r If you want to change the existing configuration, select the command OnlineGo
online to open the Assignment of offline controllers dialog box and change the settings.
r With an online connection, the »Engineer« displays the current parameter settings of
the controller with a yellow background colour.
Stop!
If you change parameters in the »Engineer« while the controller is connected
online, the changes will be directly accepted by the controller!
Vista de pagina 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 678 679

Comentarios a estos manuales

Sin comentarios