9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00312
568 Firmware 1.37 - 09/2006 L
C00312
C00313
C00314
Parameter | Name:
C00312 | CAN TPDO2 mask byte x
Data type: BITFIELD_8
Index: 24263
d
= 5EC7
h
A mask can be parameterised for each byte of the TPDO2 in the assigned subcode.
In case of an event-controlled PDO transmission, only the masked bits will be considered for event control.
Mask "0x0" means that no bit of the corresponding byte activates PDO transmission.
Mask "0xff" means that each bit of the corresponding byte can activate PDO transmission.
Value is bit-coded:
Bit 0 Mask bit 0
... ...
Bit 7 Mask bit 7
Subcodes Lenze setting Information
C00312/1 0x00 Mask for byte 1 ... byte 8 of TPDO2
C00312/...
C00312/8
; Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00313 | CAN TPDO3 mask byte x
Data type: BITFIELD_8
Index: 24262
d
= 5EC6
h
A mask can be parameterised for each byte of the TPDO3 in the assigned subcode.
In case of an event-controlled PDO transmission, only the masked bits will be considered for event control.
Mask "0x0" means that no bit of the corresponding byte activates PDO transmission.
Mask "0xff" means that each bit of the corresponding byte can activate PDO transmission.
Value is bit-coded:
Bit 0 Mask bit 0
... ...
Bit 7 Mask bit 7
Subcodes Lenze setting Information
C00313/1 0x00 Mask for byte 1 ... byte 8 of TPDO3
C00313/...
C00313/8
; Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00314 | CAN TPDO4 mask byte x
Data type: BITFIELD_8
Index: 24261
d
= 5EC5
h
A mask can be parameterised for each byte of the TPDO4 in the assigned subcode.
In case of an event-controlled PDO transmission, only the masked bits will be considered for event control.
Mask "0x0" means that no bit of the corresponding byte activates PDO transmission.
Mask "0xff" means that each bit of the corresponding byte can activate PDO transmission.
Value is bit-coded:
Bit 0 Mask bit 0
... ...
Bit 7 Mask bit 7
Subcodes Lenze setting Information
C00314/1 0x00 Mask for byte 1 ... byte 8 of TPDO4
C00314/...
C00314/8
; Read access ; Write access CINH PLC STOP No transfer COM MOT