Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37 Manual de usuario Pagina 161

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 679
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 160
L Firmware 1.37 - 09/2006 161
9400 HighLine | Parameter setting & configuration
Basic drive functions
Manual jog | Executing manual jog
9.4.2.3 Retracting of an activated limit switch
By setting MAN_bReleaseLimitSwitch to TRUE a retraction from an activated limit switch is
possible. Travel in the retracting direction until the limit switch is not active anymore.
r If, while retracting, a direction is selected additionally via the control inputs
MAN_bJogPositive or MAN_bJogNegative towards the retracting direction, the travel is
continued even the limit switch has been abandoned until MAN_bJogPositive or
MAN_bJogNegative are reset to FALSE.
r If the direction is selected against the retracting direction, the drive stops and a
corresponding status is output via the status output MAN_dnState of the system block
LS_ManualJog
.
O Tip!
An activated limit switch can also be abandoned by manual jog in retracting
direction via the control inputs MAN_bJogPositive or MAN_bJogNegative.
See also: Hardware limit positions (limit switch) (C 204)
Note!
It can only be retracted from a limit switch if this is still activated, i.e. the
corresponding limit switch input of the limiter is still active. Therefore ensure
that while travelling towards a limit switch that the trigger mechanics will not
be overtravelled by a too high mass or swing so that the limit switch will not be
activated by this.