9400 HighLine | Parameter setting & configuration
TAs for interconnection via electrical shaft
TA "Electronic gearbox" | "Homing" mode
314 Firmware 1.37 - 09/2006 L
O Tip!
Detailed information on homing can be found in chapter "Basic drive functions"
subchapter "Homing
". (C 164)
Control inputs of the function Signal configuration
Lenze setting Control input (Multiplexer parameters)
FALSE Start homing C03160/2
DigIn 2 Home mark C03160/3
C03011 Set home position C03160/4
C03012 Home position C03163
FALSE Reset home position C03160/5