9400 HighLine | Parameter setting & configuration
Standard TAs
TA "Actuator – speed" | Speed setpoint conditioning
252 Firmware 1.37 - 09/2006 L
11.2.4.2 Setpoint inversion
[11-6] Setpoint inversion (schematic diagram)
Via the digital input DI3 the effective direction of the (bipolar) setpoint can be inverted, if
required.
r Parameter setting: Application parameter tab dialog level Overview Ramp
generator
Gain Invert setpointSelection
LS_Speed...
M
Speed
setpoint
DI2DI3DI4
OUT
IN
Ramp generator
%1
%2
%15
Fixed setpoints
Status
machine
(basic drive
functions)
Speed setpoint
AIN1
M
v
Control inputs of the function Signal configuration
Lenze setting Control input (Multiplexer parameters)
DigIn 3 Invert direction of rotation C03009/1