Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37 Manual de usuario Pagina 454

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 679
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 453
9400 HighLine | Parameter setting & configuration
Diagnostics & error analysis
Error messages of the operating system
454 Firmware 1.37 - 09/2006 L
Combination MXI1/MXI2 not possible [0x00680019]
Firmware has been changed [0x0068001a]
Electronic nameplate: Communication error [0x0068001b]
Memory module: File system is faulty [0x0068001c]
Electronic nameplate: Checksum error [0x0068001d]
Firmware is not compatible [0x0068001e]
Response (Lenze setting printed in bold)
None : System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
The combinations of the extension modules plugged
into the module receptacles MXI1 & MXI2 is not
supported.
Create permitted module combination.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause Remedy
The firmware of the operating system has been updated. - (Information only)
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked : Warning Information
Cause Remedy
Communication with the electronic nameplate is
disrupted, the data could not be read.
Check correct connection of the encoder cable.
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Memory module is plugged in incorrectly or is defective. Plug in the memory module correctly.
Exchange defective memory module.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked : Warning Information
Cause Remedy
The checksum of the electronic nameplate is defective. Please contact Lenze.
Response (Lenze setting printed in bold)
None : System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Firmware is not compatible with the hardware. Transfer the compatible firmware.
Vista de pagina 453
1 2 ... 449 450 451 452 453 454 455 456 457 458 459 ... 678 679

Comentarios a estos manuales

Sin comentarios