Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37 Manual de usuario Pagina 548

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 679
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 547
9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00022
548 Firmware 1.37 - 09/2006 L
C00022
C00034
C00050
C00051
C00052
C00053
C00054
Parameter | Name:
C00022 | Maximum current
Data type: UNSIGNED_32
Index: 24553
d
= 5FE9
h
Note: In order that the motor does not start unintentionally without adjusting the route data, the maximum
current in the Lenze setting is set to "0 A"!
Setting range
(min. value | unit | max. value) Lenze setting
0.00 A 21474836.47 0.00 A
; Read access ; Write access CINH PLC STOP No transfer COM ; MOT Scaling factor: 100
Parameter | Name:
C00034 | Config. analog input 1
Data type: UNSIGNED_32
Index: 24541
d
= 5FDD
h
Selection list (Lenze setting printed in bold)
0 -10 ... +10 V
1 -20...-4 mA, +4...+20 mA
2 -20 ... +20 mA
; Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00050 | Speed setpoint
Data type: INTEGER_32
Index: 24525
d
= 5FCD
h
Display range (min. value | unit | max. value)
-480000 rpm 480000
Subcodes Information
C00050/1 Speed setpoint 1
C00050/2 Speed setpoint 2
; Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00051 | Actual speed
Data type: INTEGER_32
Index: 24524
d
= 5FCC
h
Display range (min. value | unit | max. value)
-480000 rpm 480000
; Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00052 | Motor voltage
Data type: UNSIGNED_32
Index: 24523
d
= 5FCB
h
Display range (min. value | unit | max. value)
0 V 2147483647
; Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00053 | DC bus voltage
Data type: UNSIGNED_32
Index: 24522
d
= 5FCA
h
Display range (min. value | unit | max. value)
0 V 2147483647
; Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00054 | Motor current
Data type: UNSIGNED_32
Index: 24521
d
= 5FC9
h
Display range (min. value | unit | max. value)
0.00 A 500.00
; Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Vista de pagina 547
1 2 ... 543 544 545 546 547 548 549 550 551 552 553 ... 678 679

Comentarios a estos manuales

Sin comentarios