Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37 Manual de usuario Pagina 105

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 679
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 104
L Firmware 1.37 - 09/2006 105
9400 HighLine | Parameter setting & configuration
Motor interface
System block "LS_MotorInterface"
Outputs
MI_-
bResetSpeedCtrlIntegrator
C02569/2 | BOOL
Reset integral action component in the speed controller
Signal flow - speed follower
(C 191)
TRUE Integral action component is reset to "0".
MI_dnTorqueHighLimit_n
C02568/4 | DINT
MI_dnTorqueLowLimit_n
C02568/5 | DINT
Upper/lower bipolar limit value for correcting variable of the speed controller and
total torque setpoint
Via these both inputs you can select an external torque limitation.
If the motor torque reaches the selected limits, the drive can no longer follow
the speed setpoint!
If the torque limitation is active, the output MI_bTorqueSetpointLimited is set to
TRUE.
100 % C00057/
2
When both values overlap, the upper limit value has priority.
The motor mounting position (C02527
) defines the assignment to the limitation
inputs of the motor control.
The internally effective torque limit values are displayed in C02559/1...2
.
Signal flow - motor interface
(C 95)
MI_dnReserved
DINT
Reserved input for future extensions
MI_dnFluxSetpoint_n
C02568/7 | DINT
Setpoint for the field controller
Output
DIS code | Data type
Value/meaning
MI_dwControlMode
DWORD
Active control structure of the motor control
Displayed value is bit-coded:
Bit 1 Position control without feedback, external following error
calculation
Bit 2 Position control with encoder on the motor side
Bit 3 Position control with encoder on the load side
Bit 4 Speed control
Bit 5 Torque control
MI_-
bMotorOrientationInverse
BOOL
Parameterised motor mounting position
FALSE Motor mounting position in the same direction, setpoints are not
defined.
TRUE Motor mounting position in the opposite direction, setpoints are
reversed.
MI_dwReferenceSpeed
DWORD
Parameterised motor reference speed (C00011) in [rpm]
MI_dwReferenceTorque
DWORD
Reachable motor torque with I
max_device
(C00022) in [mNm]
1000 mNm 1 Nm
Display in C00782
in [Nm]
MI_bLimitationActive
C02569/3 | BOOL
Status signal "Internal limitation active"
Group signal for all limitation messages.
TRUE One of the internal limitations is active.
MI_bPosCtrlLimited
C02569/4 | BOOL
Status signal "Phase/position controller in the limitation"
Signal flow - position follower
(C 184)
TRUE The limitation of the phase and/or position controller is active.
Input
DIS code | Data type
Information/possible settings
Vista de pagina 104
1 2 ... 100 101 102 103 104 105 106 107 108 109 110 ... 678 679