9400 HighLine | Parameter setting & configuration
Oscilloscope
Technical data
416 Firmware 1.37 - 09/2006 L
14 Oscilloscope
The integrated oscilloscope function of the 9400 High Line controller can be used as
support for commissioning, maintenance and troubleshooting.
Typical applications
r Graphical representation of any measured values (e.g. speed setpoint, actual speed and
torque)
r Detection of process values without additional measuring instruments (e.g.
oscilloscope, voltmeter and ammeter)
r Convenient documentation for fine tuning of control circuits or parameter changes of
the controller
r Documentation of production quality in the context of product liability and quality
assurance
Special features
r Recording and saving measured values in the controller
r Measuring on eight independent channels at the same time
r Measuring fast and slow signals by adjustable sample rate
r Triggering on channel, variable or error message
r Detecting measured values before and after a trigger event (pre-/post-trigger)
r Graphical representation and evaluation of measured values on a PC
r Cursor and zoom function for the measurement analysis
r Saving & loading of oscilloscope configurations
r Exporting measured values via the clipboard for further processing
14.1 Technical data
9400 HighLine
Memory depth Max. 16384 measured values, depending on the number of channels and the size of
the variables to be recorded.
Memory capacity 32768 bytes
Data width of a channel 1 ... 4 bytes, corresponding to the size of the variables to be recorded
Number of channels 1 ... 8
Trigger level Corresponding to the value range of the variable to be triggered
Trigger selection Immediate triggering, rising/falling edge, signal change
Trigger delay -100 % ... +400 %
Trigger source Channels 1 ... 8, any variable or error message
Max. time base 8 channels 32 bits each 26 hours
Max. recording time 8 channels 32 bits each 10 days