9400 HighLine | Parameter setting & configuration
Oscilloscope
Operation
426 Firmware 1.37 - 09/2006 L
14.4.6 Reading individual measured values
In addition to the zoom and the scaling function, the oscilloscope offers a "cursor function"
that can be used to display individual measured values of a selectable channel or the
difference between two measured values.
r If the Cursor tab is on top, the cursor function is active and two movable vertical
measuring lines are shown in the oscillograph.
M How to use the cursor function:
1. Select the Cursor tab.
2. Select the channel for which individual measured values are to be indicated from
the Channel list field.
3. Hold down the left mouse button and drag the red vertical measuring line to the
desired position.
The active measuring line is represented by a continuous line, the inactive
measuring line is indicated by a dotted line.
If you position the mouse pointer over the inactive measuring line, the
measuring line automatically becomes active.
The value measured at the position of the active measuring line is indicated in
the Value group box.
The difference between the values measured at the two measuring lines is
indicated in the Difference group box.