Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37 Manual de usuario Pagina 128

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 679
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 127
9400 HighLine | Parameter setting & configuration
I/O terminals
Monitoring function "State bus"
128 Firmware 1.37 - 09/2006 L
7.6.1 Detecting the current status
Use the output DIGIN_bStateBusIn of the system block LS_DigitalInput to display the
current state bus status. If an error occurs, the output DIGIN_bStateBusIn is set to TRUE.
7.6.2 Setting the state bus to the status "Error"
If the input DIGOUT_bStateBusOut of the system block LS_DigitalOutput is set to TRUE, the
state bus is set to "Error" and all connected devices start their pre-programmed response.
LS_DigitalInput
DIGIN_bStateBusIn
CONTROL
GE
24E
SB
X2
LS_DigitalOutput
DIGOUT_bStateBusOut
GE
24E
SB
X2
CONTROL
Vista de pagina 127
1 2 ... 123 124 125 126 127 128 129 130 131 132 133 ... 678 679

Comentarios a estos manuales

Sin comentarios