9400 HighLine | Parameter setting & configuration
TAs for interconnection via electrical shaft
TA "Synchronism with mark synchronisation" | "Synchronism" mode"
348 Firmware 1.37 - 09/2006 L
12.3.5.3 Virtual clutch
[12-29] Function "Virtual clutch" in the signal flow (schematic diagram)
r Parameter setting: Tab Application parameter Dialog level Overview Virtual clutch
r Configuration: Tab FB editor FB ClutchElectricalShaft
nMaster value with stretch factor
o Master value with clutch

M
v
Slave
Real master/
Virtual master
C03006 = 0
v
t
Dj
Dj Dj
TP TP
Parameters Lenze setting
Value Unit
C03672 Master value with stretch factor - Unit
C03021 Activate clutch Deactivated
C03665/1 Clutch in ramp 1.000 s
C03665/2 Decoupling ramp 2.000 s
C03665/3 Stop ramp 1.000 s
C03674 Master value with clutch - Unit
Control inputs of the function Signal configuration
Lenze setting Control input (Multiplexer parameters)
DigIn 4 Close clutch C03058/13
FALSE Clutch - positive opening operation C03058/14
Vista de pagina 347