Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37 Manual de usuario Pagina 281

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 679
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 280
L Firmware 1.37 - 09/2006 281
9400 HighLine | Parameter setting & configuration
Standard TAs
TA "Actuator – torque" | Brake control
11.3.10 Brake control
[11-24] Basic function "Brake control" (schematic diagram)
O Tip!
Detailed information on brake control can be found in chapter "Basic drive
functions" subchapter "Brake control
". (C 211)
The basic function "Brake control" serves
to the wear free control and monitoring of
a holding brake.
In the simplest case, an optionally
available brake module is used.
Alternatively the holding brake can also be
controlled and monitored via the digital
inputs/outputs.
LS_ManualJog
n
t
è
ç
LS_Brake
n
t
LS_Limiter
n
t
LS_Quickstop
STOP
LS_Torque...
M
Torque
setpoint
n
t
LS_Stop
internal
status machine
DI2
DI6
DI7
DI8
DI1
Status
machine
(basic drive
functions)
Basic drive functions
M
v
F
è
ç
Note!
In the Lenze setting the brake control is switched off to reach a safe status after
mains connection.