Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37 Manual de usuario Pagina 354

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 679
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 353
9400 HighLine | Parameter setting & configuration
TAs for interconnection via electrical shaft
TA "Synchronism with mark synchronisation" | "Homing" mode
354 Firmware 1.37 - 09/2006 L
O Tip!
Detailed information on homing can be found in chapter "Basic drive functions"
subchapter "Homing
". (C 164)
Control inputs of the function Signal configuration
Lenze setting Control input (Multiplexer parameters)
FALSE Start homing C03160/2
DigIn 2 Home mark C03160/3
C03011 Set home position C03160/4
C03012 Home position C03163
FALSE Reset home position C03160/5
Vista de pagina 353
1 2 ... 349 350 351 352 353 354 355 356 357 358 359 ... 678 679

Comentarios a estos manuales

Sin comentarios