Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37 Manual de usuario Pagina 61

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 679
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 60
L Firmware 1.37 - 09/2006 61
9400 HighLine | Parameter setting & configuration
Drive interface
System block "LS_DriveInterface"
Outputs
Output
DIS code | Data type
Value/meaning
DI_dnState
C02547 | DINT
Status (bit coded)
Status signals of the momentarily enabled basic function (if available):
Bit 0 -
Bit 1 Basic function is active (signal bActive).
Bit 2 Basic function is completed (signal bDone).
Bit 3 Acceleration/deceleration phase is active (signal bAccDec).
Bit 4 -
Bit 5 CCW rotation is active (signal bCcw).
Bit 6 -
Bit 7 Reference is known
Bit 8 Brake is open.
Bit 9 Waiting for clutch condition.
Bit 10 Zero crossing detected or position = "0".
Bit 11 -
Bit 12 -
Bit 13 -
Bit 14 -
Bit 15 Fault in active basic function (group signal).
Status signals of the internal state machine for the basic functions:
Bit 16 Torque follower
active.
Bit 17 Speed follower
active.
Bit 18 Position follower
active.
Bit 19 Setpoint follower is active (group signal for bit 16 ...18).
Bit 20 Positioning
active.
Bit 21 Homing
active.
Bit 22 Manual jog
active.
Bit 23 Brake test is active.
Bit 24 Drive at standstill.
Bit 25 Drive is stopped.
Bit 26 Quick stop
active.
Bit 27 -
Bit 28 Controller is not ready.
Bit 29 Initialisation
Bit 30 State "Fault active" (signal DI_bFailActive).
Bit 31 State machine is not ready to receive setpoints.
(Group signal for bit 28 ... 30)
DI_bReady
C02549/6 | BOOL
Status signal "Controller is ready for operation"
TRUE The controller is ready for operation.
DI_bFailActive
C02549/7 | BOOL
Status signal "Error active acknowledgement is required"
TRUE A monitoring function with the "Fault" response or "Quick stop by
trouble" has been activated and the controller is in the device state
"Fault active" or "Quick stop by trouble active".
To quit the controller state the error must be acknowledged, e.g. via
the input DI_bErrorReset1...3.
Vista de pagina 60