9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00128
556 Firmware 1.37 - 09/2006 L
C00128
C00129
C00130
C00131
C00132
C00142
Parameter | Name:
C00128 | Therm. motor time constant
Data type: UNSIGNED_32
Index: 24447
d
= 5F7F
h
Setting range (min. value | unit | max. value)
0.1 min 600.0
Subcodes Lenze setting Information
C00128/1 1.0 min Therm. time constant coil
C00128/2 5.0 min Therm. time constant plates
; Read access ; Write access CINH PLC STOP No transfer COM ; MOT Scaling factor: 10
Parameter | Name:
C00129 | Brake resistance value
Data type: INTEGER_32
Index: 24446
d
= 5F7E
h
Required for monitoring of the brake resistor temperature.
Setting range
(min. value | unit | max. value) Lenze setting
0 Ohm 500 180 Ohm
; Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00130 | Max. power of brake resistor
Data type: INTEGER_32
Index: 24445
d
= 5F7D
h
Required for monitoring of the brake resistor temperature.
Setting range
(min. value | unit | max. value) Lenze setting
0 W 800000 5600 W
; Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00131 | Therm. capacity of brake resistor
Data type: INTEGER_32
Index: 24444
d
= 5F7C
h
Required for monitoring of the brake resistor temperature.
Setting range
(min. value | unit | max. value) Lenze setting
0 kWs 1000 485 kWs
; Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00132 | Max. temp. of brake resistor
Data type: INTEGER_32
Index: 24443
d
= 5F7B
h
When this temperature is reached, the brake resistor will be switched off and switched on again if the temperature
is fallen below with a hysteresis of 5 K.
Setting range
(min. value | unit | max. value) Lenze setting
0 °C 1000 200 °C
; Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00142 | Autom. restart after mains ON
Data type: UNSIGNED_32
Index: 24433
d
= 5F71
h
Starting performance of the controller after mains connection or fault
Selection list
(Lenze setting printed in bold)
0Inhibited
1Enabled
; Read access ; Write access CINH PLC STOP No transfer COM MOT