Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37 Manual de usuario Pagina 553

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 679
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 552
L Firmware 1.37 - 09/2006 553
9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00087
C00087
C00088
C00089
C00090
C00091
C00092
C00099
C00100
Parameter | Name:
C00087 | Rated motor speed
Data type: UNSIGNED_32
Index: 24488
d
= 5FA8
h
Setting range (min. value | unit | max. value) Lenze setting
50 rpm 50000 4050 rpm
; Read access ; Write access ; CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C00088 | Motor - rated current
Data type: UNSIGNED_32
Index: 24487
d
= 5FA7
h
Setting range (min. value | unit | max. value) Lenze setting
0.01 A 1500.00 1.30 A
; Read access ; Write access ; CINH PLC STOP No transfer COM ; MOT Scaling factor: 100
Parameter | Name:
C00089 | Rated motor frequency
Data type: UNSIGNED_32
Index: 24486
d
= 5FA6
h
Setting range (min. value | unit | max. value) Lenze setting
0.1 Hz 1000.0 270.0 Hz
; Read access ; Write access ; CINH PLC STOP No transfer COM ; MOT Scaling factor: 10
Parameter | Name:
C00090 | Rated motor voltage
Data type: UNSIGNED_32
Index: 24485
d
= 5FA5
h
Setting range (min. value | unit | max. value) Lenze setting
50 V 15000 225 V
; Read access ; Write access ; CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C00091 | Motor - cosine phi
Data type: UNSIGNED_32
Index: 24484
d
= 5FA4
h
Setting range (min. value | unit | max. value) Lenze setting
0.50 1.00 0.80
; Read access ; Write access ; CINH PLC STOP No transfer COM ; MOT Scaling factor: 100
Parameter | Name:
C00092 | Motor - magnetising current
Data type: UNSIGNED_32
Index: 24483
d
= 5FA3
h
Display range (min. value | unit | max. value)
0.00 A 500.00
; Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00099 | Firmware version
Data type: VISIBLE_STRING
Index: 24476
d
= 5F9C
h
Format: "xx.xx.xx.xx" (main version, subversion, release version, build number)
; Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00100 | Service code
Data type: UNSIGNED_32
Index: 24475
d
= 5F9B
h
This code is used internally by the controller and must not be overwritten by the user!
Vista de pagina 552