L Firmware 1.37 - 09/2006 531
9400 HighLine | Parameter setting & configuration
Diagnostics & error analysis
Error messages of the operating system
CAN module (MXI2) RPDO4: Telegram not received or faulty [0x00b00003]
CAN module (MXI2) RPDO5: Telegram not received or faulty [0x00b00004]
CAN module (MXI2) RPDO6: Telegram not received or faulty [0x00b00005]
CAN module (MXI2) RPDO7: Telegram not received or faulty [0x00b00006]
CAN module (MXI2) RPDO8: Telegram not received or faulty [0x00b00007]
Response (Lenze setting printed in bold) Setting: C14591/4 (; Adjustable response)
: None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
CANopen communication module in MXI2: CAN-IN 4
error
• Incorrect PDO telegram length.
• Transmission error.
• PDO time monitoring has released.
• Set the correct telegram length for the CAN master
(transmitter).
• Remove electromagnetic interference (e.g. EMC).
• Select a different time monitoring or switch off time
monitoring.
Response (Lenze setting printed in bold) Setting: C14591/5 (; Adjustable response)
: None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
CANopen communication module in MXI2: CAN-IN 5
error
• Incorrect PDO telegram length.
• Transmission error.
• PDO time monitoring has released.
• Set the correct telegram length for the CAN master
(transmitter).
• Remove electromagnetic interference (e.g. EMC).
• Select a different time monitoring or switch off time
monitoring.
Response (Lenze setting printed in bold) Setting: C14591/6 (; Adjustable response)
: None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
CANopen communication module in MXI2: CAN-IN 6
error
• Incorrect PDO telegram length.
• Transmission error.
• PDO time monitoring has released.
• Set the correct telegram length for the CAN master
(transmitter).
• Remove electromagnetic interference (e.g. EMC).
• Select a different time monitoring or switch off time
monitoring.
Response (Lenze setting printed in bold) Setting: C14591/7 (; Adjustable response)
: None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
CANopen communication module in MXI2: CAN-IN 7
error
• Incorrect PDO telegram length.
• Transmission error.
• PDO time monitoring has released.
• Set the correct telegram length for the CAN master
(transmitter).
• Remove electromagnetic interference (e.g. EMC).
• Select a different time monitoring or switch off time
monitoring.
Response (Lenze setting printed in bold) Setting: C14591/8 (; Adjustable response)
: None System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause Remedy
CANopen communication module in MXI2: CAN-IN 8
error
• Incorrect PDO telegram length.
• Transmission error.
• PDO time monitoring has released.
• Set the correct telegram length for the CAN master
(transmitter).
• Remove electromagnetic interference (e.g. EMC).
• Select a different time monitoring or switch off time
monitoring.
Comentarios a estos manuales