Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37 Manual de usuario Pagina 107

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 679
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 106
L Firmware 1.37 - 09/2006 107
9400 HighLine | Parameter setting & configuration
Motor interface
System block "LS_MotorInterface"
MI_dnActualMotorTorque_n
DINT
Current motor torque
100 % C00057/2
Display in C00774 in [Nm]
Signal flow - motor interface
(C 95)
MI_dnActualMotorSpeed_n
DINT
Current speed of the motor shaft in [%]
100 % Motor reference speed (C00011
)
Signal flow - encoder evaluation
(C 109)
MI_dnActualMotorSpeed_s
DINT
Current speed of the motor shaft in [rpm]
•Display under C00772
Signal flow - encoder evaluation (C 109)
MI_dnActualMotorPos_p
DINT
Current position of the motor shaft in [increments]
•Display under C00770
Signal flow - encoder evaluation (C 109)
MI_-
dnActualDCBusVoltage_n
DINT
Actual DC-bus voltage
100 % 1000 V
Signal flow - motor interface
(C 95)
MI_dnThermalLoadDevice_n
DINT
Thermal device utilisation in [%]
Current result of the Ixt calculation.
MI_dnThermalLoadMotor_n
DINT
Thermal motor utilisation in [%]
Current result of the I
2
xt calculation.
Output
DIS code | Data type
Value/meaning
Vista de pagina 106