Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37 Manual de usuario Pagina 296

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 679
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 295
9400 HighLine | Parameter setting & configuration
TAs for interconnection via electrical shaft
Introduction | Application examples
296 Firmware 1.37 - 09/2006 L
In case of the relative synchronism with mark synchronisation, there is a position reference
between tool and web, which occurs in each register. For this, a slight correction is
superimposed to the synchronous motion with regard to the web. Such applications are,
for instance, printing machines.
For the mark synchronisation in particular the register r (the cycle of the guiding angle)
and the distance of the sensor
s from the home position of the tool (distances a
2
and a
3
)
are relevant.
Relative synchronism with mark synchronisation and real master
[12-8] Relative synchronism with real master (track)
n Real master/slave 1 (digital frequency extension module required)
o Slave 2
p Electrical shaft, implemented here via system bus (CAN).
q Register (cycle of guiding angle/guiding angle)
r Sensor for mark synchronisation
i
Slave
d v
d
v
R1
R3
1
3
i
1 3
System bus
v
i
Master/Slave
d v
R22
2
a
2
a
3
Vista de pagina 295
1 2 ... 291 292 293 294 295 296 297 298 299 300 301 ... 678 679

Comentarios a estos manuales

Sin comentarios