L Firmware 1.37 - 09/2006 175
9400 HighLine | Parameter setting & configuration
Basic drive functions
Homing | System block "LS_Homing"
Outputs
Identifier
DIS code | data type
Value/meaning
HM_dnState
C02657 | DINT
Status (bit-coded)
When the basic function is not enabled, all bits are set to "0".
Bits which are not listed are not assigned with a status (always "0").
Bit 1 Reference search is active.
Bit 2 Reference search is completed.
Bit 3 Acceleration/deceleration phase is active.
Bit 5 CCW rotation is active.
Bit 7 Reference is known
Bit 15 Error in basic function active (group signal).
Bit 16 Pre-stop (home switch) has been detected.
Bit 17 Touch probe/zero pulse has been detected.
Bit 21 Profile data are limited by basic function "Limiter
".
Bit 22 Traversing direction is inhibited by basic function "Limiter
".
Bit 23 Abort by basic function "Limiter
".
Bit 25 Stopping is active.
(Homing is enable but not active or speed 0)
Bit 30 Profile generation error.
HM_bEnabled
C02659/6 | BOOL
Status output "Basic function is enabled"
TRUE Homing via the control inputs is possible.
The enable input HM_bEnable is set to TRUE and the controller is
in the function state "Homing active".
HM_bActive
C02659/7 | BOOL
Status output "Basic function is active"
TRUE Reference search is active (the drive axis is moving).
HM_bDone
C02659/8 | BOOL
Status output "Basic function is completed"
TRUE Reference search is completed.
Output is reset to FALSE when input HM_bActivateHoming is
reset to FALSE.
HM_bHomePosAvailable
C02659/9 | BOOL
Status output "Reference is known"
TRUE The drive knows the home position.