9400 HighLine | Parameter setting & configuration
TAs for interconnection via electrical shaft
TA "Synchronism with mark synchronisation" | Assignment of the I/O terminals
336 Firmware 1.37 - 09/2006 L
12.3.2.2 Actual value and status signals
The following tables contain the Lenze assignment of the analog and digital outputs for
the technology application "Synchronism".
r The default signal configuration if required can be easily changed by parameterising
the multiplexer parameters assigned.
Analog outputs
Digital outputs
State bus
Display elements
Terminal X3 Signal (Lenze setting) Signal configuration
AO1 Motor speed
• Scaling: ±10 V ≡ motor reference speed (C00011
)
C03110/1
AO2 Motor torque (setpoint)
• Scaling: ±10 V ≡ Motor reference torque (C00057/2
)
C03110/2
I/O terminalsAnalog outputs (C 120)
Terminal X4 Signal (Lenze setting) Signal configuration
DO1 Status "Drive ready"
• This operating state is active if the controller is enabled by setting
the digital input RFR to HIGH level and no error has occurred.
C03100/1
DO2 Status "Electrical shaft enabled" C03100/2
DO3 Status "Limitation active"
• A setpoint is limited at the moment.
C03100/3
DO4 "Error" status
• If the controller is in the error state, the digital output DO4 is set
to HIGH level.
C03100/4
I/O terminalsDigital outputs (C 125)
Terminal X2 Signal (Lenze setting) Signal configuration
SB "Application error" status
• The state bus is put in the "error" status.
C03100/5
I/O terminalsMonitoring function "State bus" (C 127)
User LED Signal (Lenze setting) Signal configuration
Status "Electrical shaft enabled" C03100/6
Drive interfaceLED status displays (C 34)
GA
AO1
AO2
GO
24O
DO1
DO2
DO3
DO4
GE
24E
SB