9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C02109
614 Firmware 1.37 - 09/2006 L
C02109
C02113
C02121
C02122
C02123
C02520
Parameter | Name:
C02109 | Program runtime
Data type: UNSIGNED_16
Index: 22466
d
= 57C2
h
Display range (min. value | unit | max. value)
0 μs 65535
; Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02113 | Program name
Data type: VISIBLE_STRING
Index: 22462
d
= 57BE
h
; Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02121 | Runtime task 1
Data type: UNSIGNED_32
Index: 22454
d
= 57B6
h
Display range (min. value | unit | max. value)
0 μs 3600000000
Subcodes Information
C02121/1 Curr. runtime task 1
C02121/2 max. runtime task 1
; Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02122 | Runtime task 2
Data type: UNSIGNED_32
Index: 22453
d
= 57B5
h
Display range (min. value | unit | max. value)
0 μs 3600000000
Subcodes Information
C02122/1 Curr. runtime task 2
C02122/2 max. runtime task 2
; Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02123 | Runtime task 3
Data type: UNSIGNED_32
Index: 22452
d
= 57B4
h
Display range (min. value | unit | max. value)
0 μs 3600000000
Subcodes Information
C02123/1 Curr. runtime task 3
C02123/2 max. runtime task 3
; Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02520 | Gearbox fact. numer. motor
Data type: INTEGER_32
Index: 22055
d
= 5627
h
Drive interface
Setting range (min. value | unit | max. value) Lenze setting
1 2147483647 1
; Read access ; Write access ; CINH PLC STOP No transfer COM MOT