L Firmware 1.37 - 09/2006 221
9400 HighLine | Parameter setting & configuration
Basic drive functions
Brake control | Parameter setting
Further torque feedforward control options
[9-17] Feedforward control with parameterised starting torque
Application example:
The load for a hoist drive is always known. For an optimum behaviour a torque
proportional to the load and 10 Nm in addition as constant precontrol value are to be
loaded in the speed controller.
r The starting torque 1 is used as constant precontrol value (C02586
="10 Nm",
C02588
="0" and BRK_bStartingTorque2 =FALSE).
r Via the input BRK_dnTorqueAdd_n the torque is specified proportional to the load.
r An additional precontrol value can be
set via the input BRK_dnTorqueAdd_n.
1
0
BRK_dnTorqueAdd_n
CTRL
Speed controller