L Firmware 1.37 - 09/2006 151
9400 HighLine | Parameter setting & configuration
Basic drive functions
Standard stop | System block "LS_Stop"
9.2.3 System block "LS_Stop"
The LS_Stop system block in the function block editor maps the basic function "Stop".
Outputs
Identifier
DIS code | Data type
Value/meaning
STP_dnState
C02616 | DINT
Status (bit-coded)
When the basic function is not active, all bits are set to "0".
Bits which are not listed are not assigned with a status (always "0").
Bit 1 Drive is braked to standstill.
The internal state machine is in the function state "Drive is
stopped".
Bit 2 Drive is at standstill.
The internal state machine is in the function state "Drive in
standstill".
Bit 3 Deceleration phase is active.
Bit 5 CCW rotation is active.
STP_bStopActive
C02617 | BOOL
Status output "stop is active"
TRUE The drive is braked to standstill or is at standstill.
The internal state machine is in the function state "Drive is
stopped" or in the function state "Drive in standstill".
STP_dnState
STP_bStopActive
n
t
LS_Stop
Activate stopping
(internal status machine)