Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37 Manual de usuario Pagina 589

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 679
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 588
L Firmware 1.37 - 09/2006 589
9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00582
C00582
C00583
C00584
C00585
Parameter | Name:
C00582 | Resp. to heatsink temp. > C00122
Data type: UNSIGNED_32
Index: 23993
d
= 5DB9
h
Response, if heatsink temperature > variable limit temperature (C00122)
Selection list
(Lenze setting printed in bold)
0 No response
1 Error
5 Warning
; Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00583 | Resp. to motor overtemp. KTY
Data type: UNSIGNED_32
Index: 23992
d
= 5DB8
h
Response, if motor temperature > fixed limit temperature
Selection list
(Lenze setting printed in bold)
0 No response
1 Error
5 Warning
; Read access ; Write access CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C00584 | Resp. to motor temp. > C00121
Data type: UNSIGNED_32
Index: 23991
d
= 5DB7
h
Response, if motor temperature > variable limit temperature (C00121)
Selection list
(Lenze setting printed in bold)
0 No response
1 Error
5 Warning
; Read access ; Write access CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C00585 | Resp. to motor overtemp. PTC
Data type: UNSIGNED_32
Index: 23990
d
= 5DB6
h
Response, if motor temperature above PTC input T1/T2 too high
Selection list
(Lenze setting printed in bold)
0 No response
1 Error
5 Warning
; Read access ; Write access CINH PLC STOP No transfer COM ; MOT
Vista de pagina 588
1 2 ... 584 585 586 587 588 589 590 591 592 593 594 ... 678 679

Comentarios a estos manuales