Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37 Manual de usuario Pagina 25

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 679
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 24
L Firmware 1.37 - 09/2006 25
9400 HighLine | Parameter setting & configuration
Introduction
Signal types & scaling
2.3 Signal types & scaling
It is very helpful for the parameter setting & configuration of the controller to know the signal types and their scaling listed in the following table, which serve to
process physical sizes (e.g. a speed or position) in a function block configuration.
Signal type
Unit Connection
symbol in
the FB editor
Resolution
Scaling
external internal
Range
Number of
decimal
positions
Identifier
suffix
Position Increments u / w 32 bits 1 motor revolution 2
16
increments -2
31
... 2
31
-1 increments 3 _p
Speed rpm s / t 16 bits 15000 rpm 2
14
16384 ± 30000.0 rpm 1 _v
x 32 bits 15000 rpm 2
26
67108864 ± 480000.0 rpm 1 _s
Speed variation/time rpm/s v 32 bits 15000000 rpm/s 2
22
4194304 ± 7.69 * 10
9
rpm/s 3 _x
Scaled signal % z 32 bits 100 % 2
30
1073741824 ± 200.00 % 2 _n
y 16 bits 100 % 2
14
16384 ± 199.99 % 2 _a
Control/status signal { 1 bit 0 FALSE; 1 TRUE 0 / 1 0
Time s | 28 bits 0 ... 268435.456 s 3
Status word | 32 bits -2147483648 ... 2147483647
(0000 0000
hex
... FFFF FFFF
hex
)
0
Not standardised |
O Tip!
Only inputs/outputs of the same signal type (with the same
connection symbol) can be connected in the function block editor of
the »Engineer«.
Non-standardised inputs/outputs can be connected if the input and
output have the same resolution.
Vista de pagina 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 678 679

Comentarios a estos manuales

Sin comentarios